From: =?utf-8?Q?=C3=9Cllar_Aun?= <ullar.aun@lumicapital.eu>
To: =?utf-8?Q?Vassil_Hart=C5=A1uk?= <vassil.hartsuk@paasteamet.ee>
Cc: =?utf-8?B?UMOEQSBQw7VoamE=?= <pohja@paasteamet.ee>
Subject: =?utf-8?Q?Raadiku_8_kortermajade_garaa=C5=BEid?=
Date: Mon, 29 Sep 2025 17:45:47 +0300
Message-ID: <DB4PR03MB9506AAD12219D7B29C0DF6FA891BA@DB4PR03MB9506.eurprd03.prod.outlook.com>
MIME-Version: 1.0
Content-Type: multipart/alternative;
	boundary="----=_NextPart_000_0065_01DC41DD.A19EA9A0"
X-Mailer: Microsoft Outlook 16.0
Thread-Index: AdwxSkzJRK4jzOqrTbKH5vp06k/5ng==
Content-Language: en-us
x-ms-exchange-organization-originalclientipaddress: 78.28.74.134
x-ms-exchange-organization-originalserveripaddress: 2603:10a6:10:3f6::5
X-MS-Has-Attach: 
X-MS-TNEF-Correlator: 

This is a multipart message in MIME format.

------=_NextPart_000_0065_01DC41DD.A19EA9A0
Content-Type: text/plain;
	charset="utf-8"
Content-Transfer-Encoding: 8bit

Tere, Vassil



Kahjuks ei olnud võimalik veebikeskkonnas aega broneerida (Oktoobri kuu 
graafikut ei ole avatud), seega tülitan meili teel.



Suhtlesime eelnevalt Raadiku 8 rõdude konstruktsioonide osas, et kas 
tuletõkke võõba paksust väliskeskkonnas olevatel metallkonstruktsioonidel 
saab vähendada või mitte

Otsustasime, et jätame kõik vastavalt nagu esialgses projektis oli, ehk E60 
klassiga.



Sama hoonega on meil probleem maja all olevas garaažis kasutatud 
isolatsioonimaterjaliga

Situatsioon

Garaaž oli originaalis avatud ja siis tehti projekt, et see sulgeda. Sellel 
projektil on ka Päästeameti kooskõlastus.

Garaaži avatud seinte osad ehitati kinni Columbia Kivi blokkidest 
(täidetud), mille puudub soojuse isoleerimise omadus. Tulemuseks külmadel 
perioodidel on väga tugev kondenseerumine ja tugev hallitus seintel.

Seoses sellega oli ainus võimalus parkla seinad seest poolt katta ja värvida 
50mm XPS300 materjaliga (niiskuse juhtivuse takistamiseks, samas hoides ära 
kondenseerumise tekke).



Suhtlesime Tulipunene OÜ spetsialistidega ja saime info, et olukorra 
vastavalt ära lahendada tuleks XPS materjal katta T2 materjaliga

(5) Hoone siseseina, vahelae ja põranda soojustamisel kasutatakse üldjuhul 
soojustusmaterjali, mis vastab vähemalt tuletundlikkusele B. Kui kasutatakse 
soojustusmaterjali, mille tuletundlikkus on vahemikus C–E, tuleb see katta 
vähemalt A2 tuletundlikkusega ehitusmaterjali- või tootega.



Probleem on selles, et XPS300 puhul ei ole tulekindluse teksti tehtud ehk 
justkui ei mahu see selle tõttu valemisse. Kuigi E klass on põhimõtteliselt 
samuti tulekindluseta.



Millised võimalused meil siin on.

Probleem on selles mõttes tõsine, et kondenseerumist ja hallitust ei ole 
võimalik kuidagi ilma isolatsioonita ära kaotada. Meil on ventilatsioon 
sinna alasse ehitatud, aga külmemate ilmadega siiski autodest tekkinud sula 
vesi ja maapinna soojus tekitavad olukorra, kus seinad hakkavad igal juhul 
kondenseeruma.



Kas me saame lahendada olukorra selliselt, et katame isoleeritud seinte osad 
nt tulekindla kipsplaadiga (mis peaks T2 tulekindluse klassiga olema)?

Või on siin veel mingeid paremaid lahendusi?



Tervitades

Üllar Aun
Portfolio Technical Advisor

Lumi Capital
 <http://www.lumicapital.eu/> www.lumicapital.eu

Mobile: +372 5139217
Address: Pärnu mnt 31 | 10119 Tallinn | Estonia




------=_NextPart_000_0065_01DC41DD.A19EA9A0
Content-Type: text/html;
	charset="utf-8"
Content-Transfer-Encoding: quoted-printable

<html xmlns:o=3D"urn:schemas-microsoft-com:office:office" =
xmlns:w=3D"urn:schemas-microsoft-com:office:word" =
xmlns:m=3D"http://schemas.microsoft.com/office/2004/12/omml" =
xmlns=3D"http://www.w3.org/TR/REC-html40"><head>
<meta http-equiv=3D"Content-Type" content=3D"text/html; =
charset=3Dutf-8">
<meta name=3D"Generator" content=3D"Microsoft Word 15 (filtered =
medium)">
<style><!--
/* Font Definitions */
@font-face
	{font-family:"Cambria Math";
	panose-1:2 4 5 3 5 4 6 3 2 4;}
@font-face
	{font-family:Calibri;
	panose-1:2 15 5 2 2 2 4 3 2 4;}
/* Style Definitions */
p.MsoNormal, li.MsoNormal, div.MsoNormal
	{margin:0cm;
	font-size:12.0pt;
	font-family:"Calibri",sans-serif;
	mso-ligatures:standardcontextual;}
span.EmailStyle17
	{mso-style-type:personal-compose;
	font-family:"Calibri",sans-serif;
	color:windowtext;}
.MsoChpDefault
	{mso-style-type:export-only;}
@page WordSection1
	{size:612.0pt 792.0pt;
	margin:72.0pt 72.0pt 72.0pt 72.0pt;}
div.WordSection1
	{page:WordSection1;}
--></style>
</head>
<body lang=3D"EN-US" link=3D"#0563C1" vlink=3D"#954F72" =
style=3D"word-wrap:break-word">
<div class=3D"WordSection1">
<p class=3D"MsoNormal"><span lang=3D"ET">Tere, =
Vassil<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Kahjuks ei olnud v=C3=B5imalik =
veebikeskkonnas aega broneerida (Oktoobri kuu graafikut ei ole avatud), =
seega t=C3=BClitan meili teel.<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Suhtlesime eelnevalt Raadiku 8 =
r=C3=B5dude konstruktsioonide osas, et kas tulet=C3=B5kke =
v=C3=B5=C3=B5ba paksust v=C3=A4liskeskkonnas olevatel =
metallkonstruktsioonidel saab v=C3=A4hendada v=C3=B5i =
mitte<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Otsustasime, et j=C3=A4tame =
k=C3=B5ik vastavalt nagu esialgses projektis oli, ehk E60 =
klassiga.<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Sama hoonega on meil probleem =
maja all olevas garaa=C5=BEis kasutatud =
isolatsioonimaterjaliga<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span =
lang=3D"ET">Situatsioon<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Garaa=C5=BE oli originaalis =
avatud ja siis tehti projekt, et see sulgeda. Sellel projektil on ka =
P=C3=A4=C3=A4steameti koosk=C3=B5lastus.
<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Garaa=C5=BEi avatud seinte osad =
ehitati kinni Columbia Kivi blokkidest (t=C3=A4idetud), mille puudub =
soojuse isoleerimise omadus. Tulemuseks k=C3=BClmadel perioodidel on =
v=C3=A4ga
<b>tugev kondenseerumine</b> ja <b>tugev hallitus =
seintel</b>.<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Seoses sellega oli ainus =
v=C3=B5imalus parkla seinad seest poolt katta ja v=C3=A4rvida 50mm =
XPS300 materjaliga (niiskuse juhtivuse takistamiseks, samas hoides =
=C3=A4ra kondenseerumise tekke).<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Suhtlesime Tulipunene O=C3=9C =
spetsialistidega ja saime info, et olukorra vastavalt =C3=A4ra lahendada =
tuleks XPS materjal katta T2 materjaliga<o:p></o:p></span></p>
<p class=3D"MsoNormal"><i><span lang=3D"ET" =
style=3D"font-size:10.5pt;font-family:&quot;Arial&quot;,sans-serif;color:=
#202020;background:white">(5) Hoone siseseina, vahelae ja p=C3=B5randa =
soojustamisel kasutatakse =C3=BCldjuhul soojustusmaterjali, mis vastab =
v=C3=A4hemalt tuletundlikkusele&nbsp;B.
 Kui kasutatakse soojustusmaterjali, mille tuletundlikkus on vahemikus =
C=E2=80=93E, tuleb see katta v=C3=A4hemalt A2 tuletundlikkusega =
ehitusmaterjali- v=C3=B5i tootega.</span></i><span =
lang=3D"ET"><o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Probleem on selles, et XPS300 =
puhul ei ole tulekindluse teksti tehtud ehk justkui ei mahu see selle =
t=C3=B5ttu valemisse. Kuigi E klass on p=C3=B5him=C3=B5tteliselt samuti =
tulekindluseta.<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Millised v=C3=B5imalused meil =
siin on.<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Probleem on selles m=C3=B5ttes =
t=C3=B5sine, et kondenseerumist ja hallitust ei ole v=C3=B5imalik =
kuidagi ilma isolatsioonita =C3=A4ra kaotada. Meil on ventilatsioon =
sinna alasse ehitatud, aga k=C3=BClmemate ilmadega siiski autodest =
tekkinud sula
 vesi ja maapinna soojus tekitavad olukorra, kus seinad hakkavad igal =
juhul kondenseeruma.<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">Kas me saame lahendada olukorra =
selliselt, et katame isoleeritud seinte osad nt tulekindla kipsplaadiga =
(mis peaks T2 tulekindluse klassiga olema)?<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET">V=C3=B5i on siin veel mingeid =
paremaid lahendusi?<o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
<p class=3D"MsoNormal"><span =
lang=3D"ET">Tervitades<o:p></o:p></span></p>
<p class=3D"MsoNormal" style=3D"margin-bottom:6.0pt"><b><span =
lang=3D"ET" =
style=3D"font-size:9.0pt;font-family:&quot;Arial&quot;,sans-serif;color:#=
002060">=C3=9Cllar Aun</span></b><span lang=3D"ET" =
style=3D"font-size:9.0pt;font-family:&quot;Arial&quot;,sans-serif">&nbsp;=
</span><span lang=3D"ET" style=3D"font-size:11.0pt"><br>
Portfolio Technical Advisor&nbsp;<o:p></o:p></span></p>
<p class=3D"MsoNormal" style=3D"margin-bottom:6.0pt"><span lang=3D"ET" =
style=3D"font-size:9.0pt;font-family:&quot;Arial&quot;,sans-serif">Lumi =
Capital&nbsp;</span><span lang=3D"ET" style=3D"font-size:11.0pt"><br>
<a href=3D"http://www.lumicapital.eu/" target=3D"_blank" =
title=3D"http://www.lumicapital.eu/"><span =
style=3D"color:blue">www.lumicapital.eu</span></a>&nbsp;<o:p></o:p></span=
></p>
<p class=3D"MsoNormal" style=3D"margin-bottom:6.0pt"><b><span =
lang=3D"ET" =
style=3D"font-size:9.0pt;font-family:&quot;Arial&quot;,sans-serif;color:#=
002060">Mobile:</span></b><span lang=3D"ET" =
style=3D"font-size:9.0pt;font-family:&quot;Arial&quot;,sans-serif">=E2=80=
=AF&#43;372 5139217&nbsp;</span><span lang=3D"ET" =
style=3D"font-size:11.0pt"><br>
</span><b><span lang=3D"ET" =
style=3D"font-size:11.0pt;font-family:&quot;Arial&quot;,sans-serif;color:=
#002060">Address:</span></b><span lang=3D"ET" =
style=3D"font-size:11.0pt;font-family:&quot;Arial&quot;,sans-serif;color:=
#002060"> P=C3=A4rnu mnt 31 | 10119 Tallinn | Estonia&nbsp;</span><span =
lang=3D"ET" style=3D"font-size:11.0pt"><o:p></o:p></span></p>
<p class=3D"MsoNormal"><span lang=3D"ET"><o:p>&nbsp;</o:p></span></p>
</div>
</body>
</html>

------=_NextPart_000_0065_01DC41DD.A19EA9A0--

